CE Marked Fire Smoke Dampers (Motorised Fire Dampers)
With the introduction of Construction Product Regulation on the 1st July 2013, all fire dampers are required to meet the product standard BS EN 15650. To achieve this standard the damper has to be tested to BS EN 1366-2 dynamic fire test. The dampers are then classified to BS EN 13501-3 that clearly states the integrity of the damper, orientation of the damper and also the way that damper was installed in the furnace (inside/outside or both).
All of our CE Marked Fire Smoke Dampers have been tested both inside and outside of the furnace.
Advanced Air 2530 CE
The model 2530 CE is designed to prevent the spread of fire and smoke through ventilation ductwork in walls and floors. From receiving an alarm the power to the damper actuator is removed releasing the actuator spring to close the damper. The dampers also includes an electrical thermal release that will close the damper when the local temperature reaches 72°C.
The damper has been tested from both sides in both wall and floor installations so there is no issue in coordination caused by working out which side the fire will be on. The damper is supplied complete with the actuator and ETR (with test button) factory fitted. The dampers can be supplied with long spigots for installing access doors (optional) or short spigots where space is limited.
Advanced Air 2550 CE
The model 2550 CE is designed to prevent the spread of fire and smoke through ventilation ductwork in walls and floors. From receiving an alarm the power to the damper actuator is removed releasing the actuator spring to close the damper. The dampers also includes an electrical thermal release and a secondary mechanical fusible link that will close the damper when the local temperature reaches 72°C.
The damper has been tested from both sides in both wall and floor installations so there is no issue in coordination caused by working out which side the fire will be on. The damper is supplied complete with the actuator and ETR (with test button) factory fitted. The dampers can be supplied with long spigots for installing access doors (optional) or short spigots where space is limited.
Advanced Air 0400 CE (Circular only)
The model 0400 CE is designed to prevent the spread of fire and smoke through ventilation ductwork in walls. From receiving an alarm the power to the damper actuator is removed releasing the actuator spring to close the damper. The dampers also includes an electrical thermal release that will close the damper when the local temperature reaches 72°C.
The damper has been tested from both sides in wall installations so there is no issue in coordination caused by working out which side the fire will be on. The damper is supplied complete with the actuator and ETR (with test button) factory fitted.